====== Connection Hardware PC CADDIE.id card systems ====== Here you can view information on the connection, wiring and pin assignment as well as the dimensions of the most common card readers for Pcc.id online and Pcc.id offline card systems or download and print them as PDF files. ===== PC CADDIE.id online card systems ===== ==== MOXA NPort Serial Server ==== Each MOXA requires a fixed **IP address**. You must clarify which addresses may be assigned to the MOXA(s) in your network **with your IT manager before installation**. If possible, the IP address for the MOXAs should be specified at the time of ordering so that it can be set before despatch. The IP can be subsequently changed using the macro //moxa// macro: {{de:einstellungen:kartensystem:moxa_config1.png?direct|}} - The MOXA tool finds the connected NPort devices even if their IP address is not known - Select the serial server to be configured - Call up the configuration dialogue {{de:einstellungen:kartensystem:moxa_config2.png?direct|}} - Click on the tab //Network// tab - To change the IP, the //Modify//-box must be ticked - Enter the desired IP - Confirm with //OK// confirm :!: Please do not change any other options. TIP If there are several MOXAs in the network, they can be distinguished by their MAC address. The MAC address can be found on the type plate. ===== Reader connection diagrams ===== ==== Minova MCR08 with display (MOXA) ==== === to Moxa === {{ de:einstellungen:kartensystem:anschlussplan_minova_mcr08_rs485.pdf |Minova MCR08 to Moxa 5232 connection diagram online}} {{de:einstellungen:kartensystem:minova_mcr08_rs485_v1.png?720|}} ==== Minova MCR08 with display (BARIX) ==== === to Barix === {{ de:einstellungen:kartensystem:minova_mcr08_barix.pdf |Minova MCR08 to Barix 5232 connection diagram online}} {{de:einstellungen:kartensystem:minova_mcr08_barix.png?720|}} [[intern:support_technik:technik:pccaddieid:barix_barionet50|Barix configuration]] ==== Ellipson reader ==== {{de:einstellungen:kartensystem:phg_-_ellipson_anschlussplan.pdf|Wiring diagram online PHG - Ellipson}} {{de:einstellungen:kartensystem:phg_-_ellipson_anschlussplan.png?720&direct|}} :!: Please note with regard to relays: the maximum contact load capacity is 24V / 2 A (resistive load)! ==== Voxio reader ==== {{de:einstellungen:kartensystem:phg_-_voxio_anschlussplan_2.pdf|Wiring diagram online PHG Voxio}} {{de:einstellungen:kartensystem:phg_-_voxio_anschlussplan_2.png?direct&720|Wiring diagram online PHG Voxio}} :!: Please note with regard to relays: the maximum contact load capacity is 24V / 2 A (resistive load)! ==== Voxio display reader ==== {{de:einstellungen:kartensystem:anschluss_voxio_display_rs485.pdf|Wiring diagram online Voxio Display}} {{de:einstellungen:kartensystem:anschluss_voxio_display_rs485.png|Wiring diagram online Voxio Display}} ==== Voxio Touch Reader ==== {{de:einstellungen:kartensystem:anschluss_voxio_touch_rs485.pdf|Wiring diagram online Voxio Touch}} {{de:einstellungen:kartensystem:anschluss_voxio_touch_rs485.png|Wiring diagram online Voxio Touch}} ==== Voxio Touch Display Reader ==== {{de:einstellungen:kartensystem:anschlussplan_voxio_touch_display_online.pdf|Wiring diagram online Voxio Touch Display}} {{de:einstellungen:kartensystem:anschluss_voxio_touch_display_online.png|Wiring diagram online Voxio Touch Display}} ==== Voxio frame reader ==== {{ de:einstellungen:kartensystem:anschluss_voxio_z.pdf |Wiring diagram online Voxio frame}} {{de:einstellungen:kartensystem:anschluss_voxio_z.png|Wiring diagram online Voxio frame}} ==== I/O controller with 2 relays RS485 ==== {{de:einstellungen:kartensystem:phg_anschluss_relais_rs485.pdf|Wiring diagram I/O 2 relay controller RS485}} {{de:einstellungen:kartensystem:rs485_relais.png|Wiring diagram I/O Controller 2 Relay RS485}} ==== I/O Controller with 4 relays RS485 ==== {{de:einstellungen:kartensystem:anschlussplan_io_4relais_rs485.pdf|Wiring diagram I/O Controller 4 relays RS485}} {{de:einstellungen:kartensystem:anschluss_io_4relais_rs485.png?direct&600|Wiring diagram I/O Controller 4 Relay RS485}} ==== Oris reader ==== {{de:einstellungen:kartensystem:pc_caddie.id_anschlussplan_rs485_-_online_phg_oris.pdf|Wiring diagram online PHG Oris}} {{de:einstellungen:kartensystem:pc_caddie.id_anschlussplan_rs485_-_online_phg_oris.png?direct&720|Wiring diagram online PHG Oris}} :!: Please note with regard to relays: the maximum contact load capacity is 24V / 2 A (resistive load)! ==== Quio reader ==== {{de:einstellungen:kartensystem:pc_caddie.id_anschlussplan_rs485_-_online.pdf|Wiring diagram online Quio}} {{de:einstellungen:kartensystem:pc_caddie.id_anschlussplan_rs485_-_online.png?720&direct|Wiring diagram online Quio}} :!: Please note with regard to relays: the maximum contact load capacity is 24V / 2 A (resistive load)! ==== Quio reader with RS485 isolator ==== {{de:einstellungen:kartensystem:anschluss_pcc5600_mit_rs485_isolator.pdf|Connection diagram online with RS485 isolator}} {{de:einstellungen:kartensystem:anschluss_pcc5600_mit_rs485_isolator.png?720&direct|Wiring diagram online with RS485 isolator}} :!: Please note with regard to relays: the maximum contact load capacity is 24V / 2 A (resistive load)! ===== PC CADDIE.id offline card systems ===== ==== Systems from 2018 (silver) ==== {{ de:einstellungen:kartensystem:offlinesystem2_anschlussplan.pdf |Offline connection diagram}} {{de:einstellungen:kartensystem:anschlussplanofflinesystem2minovamcr08.png?direct&400|Wiring diagram offline Minova}} {{de:einstellungen:kartensystem:offlinesystem2_anschlussplan_touch.png?direct&400|Wiring diagram offline Touch}} {{de:einstellungen:kartensystem:offlinesystem2_anschlussplan_display.png?direct&400|Wiring diagram offline Display}} ==== Systems up to 2017 (light grey) ==== The connection for triggering the balls (for ball machines) or for switching the normally closed solenoid (for doors) is located on the screwable plug-in strip of the CPU (mini PC). The Quio reader also contains a relay, which can be used as an alternative to the CPU if safety is not the top priority. :!: Please note with regard to the relay: the maximum contact load capacity is 24V / 2 A (resistive load)! {{de:einstellungen:kartensystem:anschlussplan_voxio_display_offline_cpu_v.1_.pdf|Connection diagram offline Voxio}} {{de:einstellungen:kartensystem:anschluss_voxio_display_offline_cpu_v.1_.png?720&direct|Wiring diagram offline Voxio}} {{de:einstellungen:kartensystem:pc_caddie.id_anschlussplan_rs232_-_offline.pdf|Wiring diagram offline}} {{de:einstellungen:kartensystem:pc_caddie.id_anschlussplan_rs232_-_offline.png?720&direct|Wiring diagram offline}} :!: Please note with regard to relays: the maximum contact load capacity is 24V / 2 A (resistive load)! ===== Installation and requirements ===== **Installation and requirements RS485 BUS / door reader:** {{de:einstellungen:kartensystem:online_tuer_rs485_bus.pdf|Several door readers in series}}\\ {{de:einstellungen:kartensystem:kasy_online_rs485_bus.png|}} **Mounting door reader online:** {{de:einstellungen:kartensystem:montage_online_tuer.pdf|Mounting door reader online}} {{de:einstellungen:kartensystem:kasy_online_montage.png|}} **Mounting door reader offline** {{de:einstellungen:kartensystem:montage_offline_tuer.pdf|Mounting door reader offline}} {{de:einstellungen:kartensystem:kasy_offline_montage.png|}} ===== Pre-assembly bundle for different assembly situations ===== As the card systems in the offline system have to be installed in different environments depending on the environment, and the configuration of the cables and connections requires specialist knowledge, we offer 3 different pre-assembly pre-assembly bundles tailored to your structural situation. 1. pre-assembled and tested on a top-hat rail for use in ball machines or doors with an existing installation environment 2. pre-assembled and tested on top-hat rail in surface-mounted (AP) housing 3. pre-mounted and tested on a top-hat rail in a flush-mounted (UP) cabinet PCCADDIE technicians will determine which pre-installation is the right one in your case on a case-by-case basis after the purchase. The only important thing is the purchase of the pre-installation at an all-inclusive price.